Clinical significance of anti-Sd(a) - conflicting results with tube and gel antiglobulin tests

A colleague in Virginia reports that they have discovered a patient whose serum contains anti-Sd(a), and that they would appreciate it if colleagues would share their approach to selecting blood products for such a patient. The inquiring colleague states that she has read the information provided by the current edition of the AABB Technical Manual, but feels that additional information would be helpful. Her main concern is that the anti-Sd(a) is causing problems for her laboratory with finding "compatible" units for transfusion. Up to this point, every unit they have crossmmatched using a tube method has revealed microscopic, mixed-field agglutination when the tubes are examined microscopically following an antihuman globulin test. However, their reference lab currently uses a GEL-antiglobulin methodology, and the results from this test are ruling out any incompatibility as well as any clinically significant antibodies. The inquiring colleague says that the only reason the reference lab detected the anti-Sd(a) was because of her insistence that their work-up be repeated using the tube method that the hospital uses. She adds that the reference laboratory is telling her not to worry about anti-Sd(a), but she is still wondering if anyone else in the forum has had personal experience in dealing with this antibody?


ADDENDA July 30, 2003

The following responses were received.

  1. A very experienced transfusion medicine physician in New York is of the opinion that anti-Sd(a) is not a clinically significant antibody, even though in his experience the IgM versions can fix complement, and there have been examples of IgG anti-Sd(a) and he suggests that the inquiring colleague might want to read an article that was published in Vox Sang in 1982 which he co-authored and which is summarized as follows: (Spitalnik S, et al. Vox Sang. 1982;42(6):308-12.) Pre- and post-transfusion antibody titers were performed on 6 patients with anti-Sd(a) transfused with incompatible blood. In 3 of these patients a significant rise in IgG antibody titer was found. The data suggest that in occasional patients the Sd(a) antigen does evoke a secondary immune response. We evaluated 245 pregnant women for the presence of Sd(a) and found that 30% were Sd(a-). This incidence was significantly higher than that found in normal blood donors (4%), but was lower than that described in previous reports. We found that 22% of pregnant women in their first trimester were Sd(a-) whereas at term 36% were Sd(a-). These significantly different incidences of antigen positivity suggest decreased antigen expression with progressing pregnancy, as seen in the Lewis system. No difference was found in the incidence of anti-Sd(a) between pregnant women, either during their first trimester or at term, and normal donors.] The New York physician adds that in his practice, giving antiglobulin crossmatch compatible blood would be ideal when dealing with anti-Sd(a) (which is what his transfusion service laboratory also does for Lewis blood group antibodies).  However, if no crossmatch compatible blood is available, he would authorize giving least incompatible red cells, assuming that all other antibody specificities have been ruled out. He is aware of a single case where anti-Sd(a) was reportedly the cause of a hemolytic transfusion reaction [Peetermans ME, Cole-Dergent J. Vox Sang. 1970 Jan;18(1):67-70. Haemolytic transfusion reaction due to anti-Sda. (no abstract available)], but he would not change his overall approach to this antibody as a result of that singular report. Finally, if concerned because of strong antiglobulin phase positive crossmatches with a "known to be" clinically insignificant antibody, his hospital's usual procedure is to infuse the first 30 ml or so slowly (over 30 minutes) with careful observation.  If there is no change in vital signs or clinical symptoms, the rest of the unit(s) can be given at the usual rate.

  2. The director of a highly respected immunohematology reference laboratory in Los Angeles is of the opinion that anti-Sd(a) is usually not clinically significant and he states that there are several reports in the literature of normal survival of incompatible RBCs. To quote him (verbatim) "I believe that there are only two reports of HTRs caused by anti-Sd(a) and those involved units of blood with a "super Sda" antigen. As the gel test is negative, and >90% of Europeans use only column agglutination tests (e.g., gel test) for compatibility testing, I would not be concerned about the antibody." A good review on the clinical significance of anti-Sd(a) can be found on pages 816-817 of: Issitt PD, Anstee DJ. Applied blood group serology, 4th ed. Durham, NC. Montgomery Scientific Publications, 1998.

  3. According to an expert immunohematologist in Michigan (verbatim), "the Sda (Sid) antigen, named after Sidney Smith of the Lister Institute in England, whose red cells had a strong expression of Sda, is considered identical in structure to the Cad antigen. Cad reacts with Dolichos biflorus and Glycine max (soybean) a lectins, and is expressed variably on red cells; rare Cad 1 red cells are polyagglutinable. Most Sd(a+) cells are Cad 3/4, and the transfusion reaction cases are most likely associated with the Cad 2 phenotype. Such cells are also referred to as "Super Sid" or Sd(a++) cells. The Cad (Sda) structure is also present on the Tamm-Horsfall urinary glycoprotein; hence the inhibition of anti-Sdaby urine from Sd(a+) individuals. It is most unlikely that an anti-Sd(a) that can only be found microscopically has ever caused a hemolytic transfusion reaction involving Cad 3/4 cells. Many workers do not read tests microscopically, and many use column technologies such as the gel test. There are no reports of transfusion reactions due to anti-Sda that have been missed as a consequence of these practices. This correspondent has only seen 5 examples of anti-Sda; two were referral samples from facilities that did read tests microscopically, two were received for research purposes, and one was in a patient whose serum gave macroscopic mixed-field reactivity with reagent red cells."

ADDENDA July 31, 2003

  1. A colleague in Toronto is of the opinion that it is appropriate to ignore this antibody specificity as it is usually an IgM antibody having no credible reports of clinical significance. Expression of the Sd(a) antigen on red cells is highly variable. One often finds a lack of reactivity when multiple donors are tested if microscopic readings are avoided and, especially when using anti-IgG antiglobulin reagents. Perhaps, this laboratory should consider discontinuing this practice of reading everything microscopically as there are no requirements to do so. If the transfusion laboratory would like to continue using microscopic readings and antiglobulin sera containing both anti-IgG and -Complement, the Canadian's suggestion would be to try urine neutralization of the anti-Sd(a) (described in the current edition of the AABB Technical Manual on pages 704-705), and perform crossmatches using the urine neutralized serum.

Submit comments to the e-Network Forum at enetworkforum@cbbsweb.org

Ira A. Shulman, MD
CBBS e-Network Forum Senior Editor & Moderator

W. Tait Stevens, MD
CBBS e-Network Forum Editor & Moderator

Elizabeth M. St. Lezin, MD
CBBS e-Network Forum Associate Editor & Moderator

James Iqbal, MD
CBBS e-Network Forum Associate Editor & Moderator

The e-Network Forum is supported in part by the California Blood Bank Society (CBBS) and the American Red Cross Blood Services (ARCBS) and endorses collegial discussion among blood banking and transfusion medicine professionals. However, neither the CBBS nor the ARCBS in any way endorse the specific views and opinions expressed in the forum. The forum is not intended as a substitute for medical or legal advice and the content should not be relied upon for any medical or legal purposes. Readers should make their own determinations as to: (i) what constitutes appropriate medical, technical, and administrative practices, and (ii) how best to comply with laws and regulations relevant to their questions. For the latter, they should consider consulting, as to any medical matters, a qualified physician, and, as to any legal matters, an attorney familiar with related state and federal laws. The user of the forum, by accessing same, assumes all risks arising out of such use and releases CBBS and their respective members, directors, officers and agents from and against any loss, damage, claim or liability arising out of such use of the Forum.
 
Login Join