Questions about the use of blood component recipient sets |
||
|
**The first question comes from a blood banker in Mississippi, who would like advice on a blood filtration issue with which she is struggling. According to the AABB Technical Manual, filters used for blood component transfusion (platelets, cryoprecipitate, and fresh frozen plasma) should have shorter tubing and smaller filters than those used for the transfusion of red cells. Excerpts from the 13th edition of the Technical Manual include
**The second question comes from a blood banker in Los Angeles who reports having spoken with a technical specialist at one of the blood component recipient set manufacturers. According to the Los Angeles blood banker, the technical specialist did not recommend any particular blood component recipient set for platelet versus red cell transfusions. According to the technical specialist, all of their blood and component recipient sets include the same sized drip chamber, thus residual volumes are very similar for all of the different sets. The major differences between sets are Y-type versus straight tubing and length of tubing. However, the residual volume in the tubing, regardless of length, is small compared to the drip chamber. The technical specialist finally suggested that Y-type tubing might be preferable because it provides for rinsing and thus making residual volumes a mute point. The Los Angeles blood banker is curious to know if others within the e-network employ a single type of blood administration tubing for all transfusions, or if others use a selection, and if so, what types and why? Please submit your comments regarding the selection of blood component recipient sets for transfusion of the common blood products - red cells, platelets and plasma. The following responses have been submittted. 1. A hospital in California recently went through a policy change for filters. They decided upon a Blood Component recipent set (150 micron, shorter tubing) for all plasma and platelet based transfusions, and a regular 170 micron Y set for all red cell transfusions. All their red cell units are leukocyte-reduced. Before this, red cell tubing was used for plasma and platelet transfusions also. They report that they have noticed better platelet increments since implementing the Blood Component recipient set, although this is antecdotal, as they have not done a formal study. There have been no complaints from nursing staff. ADDENDA May 28, 2002 2. A blood banker in Houston is of the opinion that the most important consideration is to make certain that the set is approved for use with whatever component is being transfused. Some infusion sets may be acceptable for red cells but will remove platelets. This was the case several years ago with one of their local hospitals who called to complain that platelet transfusions just weren't "any good anymore." Their patients were getting virtually no increment after transfusion. The responding blood banker reports that when they were asked what kind of infusion set they were using, it was discovered that the set was not 'compatible' with platelet transfusions, and as a result they were essentially transfusing plasma instead of platelets, since the filter removed most of the platelets. The Texan concludes by saying "so buyer beware...and do your homework! It is fine to use the same type of set for all components as long as it is approved for use with all components." |
|||
|
|
Please submit comments to the e-Network Forum. Ira A. Shulman, MD |
||
|
Posted: May 21, 2002
Addenda: May 28, 2002 |
|
||